  Toxo IgG, IgM, Avidity  
     
  Toxoplasma infection can cause severe damage in cases of congenitally acquired infection. The diagnosis of primary infection in pregnant women and the timing of infection are of particular importance. Serology is the only method to determine if the mother has been infected by Toxoplasma gondii. Early diagnosis of primary infection requires a highly sensitive and quantitative assay for IgG and IgM antibodies, to discriminate between chronic and recent infections. The presence of Toxoplasma-specific IgM in serum is an indicators of recent infection, but often IgM persists and may be detected for years after the occurrence of the infection. Measurement of IgG avidity may improve the accuracy of the serological diagnosis dating the infection more precisely. A high Avidity Index excludes recent Toxoplasma infection within the last four months.  
     
  Therefore the detection of a high IgG Avidity Index duringthe first trimester excludes an acute infection during pregnancy for many women who, otherwise, on the basis of a positive specific IgG and IgM result, would have been identified as having a recent infection.  
     
  DiaSorin Liaison Toxo IgG II  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 20 min
 
  DiaSorin Liaison Toxo IgM  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 20 min
 
  Diasorin Liaison TOXO IgG Avidity II  
 
  • 3-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 20 min
 
     
 
Product code Product name Method Kit Size Sample Type
310710 Liaison Toxo IgM 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
310780 Liaison Toxo IgG II 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
310790 Liaison Toxo IgG Avidity II 3-step immunoluminometric sandwich assay 25 test kit Serum, plasma
P002034 ETI-TOXOK-G PLUS ELISA 192 wells Serum, plasma
P002038 ETI-TOXOK-M reverse PLUS ELISA 96 wells Serum, plasma
P002039 ETI-TOXOK-A reverse PLUS ELISA 96 wells Serum, plasma
 
     
 
Back To Top      
  Rubella IgG, IgM  
     
  The Rubella test is used to confirm the presence of adequate protection against the Rubella virus and to detect a recent or past infection. It can also be used to identify those who have never been exposed to the virus and those who have not been vaccinated. The IgG Rubella test is ordered on all pregnant women and those planning to become pregnant to verify that they have a sufficient amount (titer) of Rubella antibodies to protect them from infection.  
     
  Both the IgM and IgG antibody tests may be ordered on a person, pregnant or not, who has symptoms of a Rubella infection. They may also be ordered on a newborn that is suspected to have become infected during pregnancy or that presents with congenital birth defects that the doctor suspects may be due to a Rubella infection.  
     
  DiaSorin Liaison Rubella IgG  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 20 min
 
  DiaSorin Liaison Rubella IgM  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 30 min
 
 
Product code Product name Method Kit Size Sample Type
310720 Liaison Rubella IgG 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
310730 Liaison Rubella IgM 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
P002036 ETI-RUBEK-M reverse PLUS (Rubella) ELISA 96 wells Serum, plasma
P002037 ETI-RUBEK-G PLUS (Rubella) ELISA 192 wells Serum, plasma
 
 
   
Back To Top      
  CMV  
     
  Human Cytomegalovirus (hCMV) is the most common cause of viral intrauterine infection. Fetal damage is mostly due to maternal primary infection. Intrauterine transmission of CMV is significantly reduced in immunoprotected mothers compared to primary infections contracted during pregnancy (< 2% vs 40-50%, respectively). As infections are either asymptomatic or accompanied by symptoms which are not specific for CMV, laboratory techniques are the sole means of diagnosing acute infections. However, the establishment of primary infection as opposed to reactivation, chronic infection, IgM persistency or polyclonal stimulation may be difficult on the basis of current classical CMV IgM and IgG detection. DiaSorin LIAISON® serology line has been developed to solve diagnostic ambiguities. Sensitive and quantitative CMV IgM, with highly specific and quantitative CMV IgG, both complemented by CMV avidity determination in a fully automated LIAISON® assay environment, will allow the laboratory to report clear and unequivocal results. Positive IgM and low-avidity IgG are suggestive of primary infection, whereas high-avidity IgG indicates IgM presence due to persistency or reactivation. In addition, to avoid misinterpretation of positive, yet low IgM responses in primary infection, the IgM test will point to the need of IgG avidity determination to overrule primary infection.  
     
  DiaSorin Liaison CMV IgG  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 20 min
 
  DiaSorin Liaison CMV IgM  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 30 min
 
  DiaSorin Liaison CMV IgG Avidity  
 
  • 3-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 30 min
 
     
 
Product code Product name Method Kit Size Sample Type
310740 Liaison CMV IgG 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
310750 Liaison CMV IgM 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
310760 Liaison CMV IgG Avidity 3-step immunoluminometric sandwich assay 25 test kit Serum, plasma
P002033 ETI-CYTOK-G PLUS ELISA 192 wells Serum, plasma
P002035 ETI-CYTOK-M revers pLUS ELISA 96 wells Serum, plasma
24300 CMV-vue Kit IFA 8x8 wells Leukocyte isolate
 
     
Back To Top    
 
  HSV  
     
  Genital herpes simplex virus (HSV) infection in pregnant women is associated with risk of viral transmission to the infant at delivery. The identification of risk pregnancies is necessary to avoid life-threatening consequences in newborns. Herpes simplex virus type 2 (HSV-2) is the main cause of genital herpes. HSV-2 reactivation or primary infection during pregnancy is common, but the risk of associated neonatal HSV-2 infection is 10 times greater for women with primary infection in the last trimester of pregnancy. Since most individuals infected with HSV-2 are asymptomatic, the serological evaluation of HSV-2 infection can reduce viral transmission. However, serological diagnosis of HSV-2 infection has been difficult, since discrimination between HSV-1 and HSV-2 specific antibodies in serum is complicated by the shared antigenicity of the two viruses and consequently by the considerable cross-reactivity. DiaSorin Liaison® serology line has been developed to solve such diagnostic ambiguities. The determination of type-specific antibodies to glycoprotein G2 allows the laboratory to establish a specific diagnosis of HSV-2 infection in a fully automated Liaison® environment. A highly specific and sensitive screening tool for determination of IgG antibodies to HSV-1 and HSV-2 as well as a complementary test for detection of Immunoglobulin M have been developed to complete the line.  
     
  DiaSorin Liaison HSV-1/2 IgG  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 20 min
 
  DiaSorin Liaison HSV-2 IgM  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 20 min
 
  DiaSorin Liaison HSV-1/2 IgM  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Incubation time: 20 min
 
 
Product code Product name Method Kit Size Sample Type
310800 Liaison HSV-1/2 IgG 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
310810 Liaison HSV-2 IgM 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
310820 Liaison HSV-1/2 IgM 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
310830 Liaison HSV-1 IgG 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
P002023 ETI-HSVK-G 1/2 (HSV-1/2 IgG) ELISA 96 wells Serum, plasma
P002024 ETI-HSVK-G 2 (HSV-2 IgG ELISA 96 wells Serum, plasma
P002025 ETI-HSVK-M 1/2 (HSV-1/2 IgM) ELISA 96 wells Serum, plasma
 
 
   
 