Back To Top |
|
|
|
|
|
|
|
|
|
Estradiol (E2) is produced in women mainly in the ovary. In men, the testes and adrenal glands are the principal source of Estradiol. In women, normal levels of Estradiol provide for proper ovulation, conception, and pregnancy, in addition to promoting healthy bone structure and regulating cholesterol levels. Estradiol levels are used to help evaluate ovarian function. Estradiol helps diagnose the cause of precocious puberty in girls and gynecomastia in men. Its main use has been in the differential diagnosis of amenorrhea (for example, to determine whether the cause is menopause, pregnancy, or a medical problem). In assisted reproductive technology (ART), serial measurements are used to monitor follicle development in the ovary in the days prior to in-vitro fertilization. Estradiol is also sometimes used to monitor menopausal hormone replacement therapy. |
|
|
|
|
|
|
|
DiaSorin Liaison Estradiol |
|
|
|
- Competitive 1-step immunoluminometric assay using directly coated magnetic microparticles
- Sample matrix: Serum, plasma
- Sample volume: 200 µl
- Incubation time: 24 min
- Measuring range: 12 – 11 pg/ml
- Detection Limit: 12 pg/ml
|
|
| |
|
|
|
|
|
Product code |
Product name |
Method |
Kit Size |
Sample Type |
|
P001905 |
ESTR-CTK-4 (Estradiol) |
RIA |
100 tubes |
Serum, plasma |
|
P2210 / P2211 |
ESTRADIOL-2 |
RIA Double Antibody |
100 tubes / 500 tubes |
Serum, plasma |
|
|
|
|
|
Back To Top |
|
|
|
|
|
|
|
|
|
Human follicle stimulating hormone (FSH) is used for the evaluation of precocious and delayed puberty in children, assessment of ovarian, pituitary or hypothalamus pathology in women (differential diagnosis of amenorrhea),
confirmation of precocious menopause (single FSH measurement) and the differential diagnosis of hypogonadism and the evaluation of impaired fertility or a chryptorchidism in men |
|
|
|
|
|
|
|
DiaSorin Liaison FSH |
|
|
|
- 1-step immunoluminometric sandwich assay using directly coated magnetic microparticles
- Sample matrix: Serum, Citrate plasma
- Sample volume: 25 µl
- Incubation time: 10 min
- Measuring range: 0.25 - 4000 mIU/ml
- Detection Limit: 0.25 mIU/ml
|
|
| |
|
|
|
|
|
Product code |
Product name |
Method |
Kit Size |
Sample Type |
|
312251 |
Liaison FSH |
1-step immunoluminometric sandwich assay |
100 test kit |
Serum, Citrate plasma |
|
P001907 |
FSH-CTK-4 |
IRMA Coated tubes (RIA) |
100 tubes |
Serum, Plasma |
|
|
|
|
|
|
|
|
Back To Top |
|
|
|
|
|
|
|
|
|
|
|
hCG is responsible for maintaining the function of the ovarian corpus luteum. In normal pregnancy, hCG concentrations rapidly increase with a doubling rate of approximately two days. Pathologically decreased values indicate abnormal pregnancy (e.g. ectopic pregnancy). A sudden fall of hCG levels before the 8th–10th week of gestation should be considered as a serious indicator of imminent abortion. If pregnancy can be excluded, hCG levels above normal are highly likely to indicate the presence of malignant neoplasm, particularly germ-cell tumors (e.g. testicular tumors, chorionic or ovarian carcinoma). For use as a tumor marker, the test system has to recognize both hCG and βhCG, since testicular and chorionic carcinomas
mainly secrete the free β-chains rather than the intact hCG molecule. |
|
|
|
|
|
|
|
DiaSorin Liaison hCG |
|
|
|
- 1-step immunoluminometric sandwich assay using directly coated magnetic microparticles
- Sample matrix: Serum
- Sample volume: 30 µl
- Incubation time: 10 min
- Measuring range: 0.5 - 5000 mIU/ml
- Detection Limit: 0.5 mIU/ml
|
|
| |
|
|
|
|
|
Product code |
Product name |
Method |
Kit Size |
Sample Type |
|
312311 |
Liaison HCG / βhCG |
1-step immunoluminometric sandwich assay |
100 test kit |
Serum |
|
|
|
|
|
|
|
|
Back To Top |
|
|
|
|
|
|
|
|
|
Luteinizing hormone is used for the evaluation of precocious and delayed puberty in children, determination of the precise date of ovulation in women (artificial insemination, in vitro fertilization, choice of a method of ovulation
induction), assessment of ovarian, pituitary or hypothalamus pathology and the differential diagnosis of hypogonadism and the evaluation of impaired fertility or a chryptorchidism in men. |
|
|
|
|
|
|
|
DiaSorin Liaison LH |
|
|
|
- 1-step immunoluminometric sandwich assay using directly coated magnetic microparticles
- Sample matrix: Serum, EDTA plasma
- Sample volume: 50 µl
- Incubation time: 10 min
- Measuring range: 0.2 – 250 mIU/ml
- Detection Limit: 0.2 mIU/ml
|
|
| |
|
|
|
|
|
Product code |
Product name |
Method |
Kit Size |
Sample Type |
|
312201 |
Liaison LH |
1-step immunoluminometric sandwich assay |
100 test kit |
Serum, EDTA plasma |
|
P001908 |
LH-CTK-4 |
IRMA Coated tubes |
100 tubes |
Serum, Plasma |
|
|
|
|
|
|
|
|
Back To Top |
|
|
|
|
|
|
|
|
|
|
|
Diencephalo-pituitary tumor pathology (Prolactinoma, craniopharyngioma,
chondroma) Prolactin is used in isolated hypogonadism, spontaneous or provoked
galactorhea, and gynecomastia Prolactin is used in sterility check-up,
particularly in women with amenorrhea or any menstrual cycle anomaly and The
long term treatment with dopaminergic drugs or with any other drugs
(neuroleptics, anti-depressants, hypotensive drugs, oral contraceptives,
cimetidine) |
|
|
|
|
|
|
|
BRAHMS Kryptor Prolactin |
|
|
|
- TRACE technology (Time resolved amplified cryptate emission)
- Sample matrix: Serum, plasma (heparin)
- Diluent included in kit
- Sample volume: 26 µl
- Incubation time: 19 min
- Direct measuring range: 5 - 4600 µIU/ml
- Range with automated dilution: 5 – 1000 000 µIU/ml
- Detection Limit: 5 µIU/ml
- Intra – assay and Inter-assay coefficients of variation are 0.64 – 3.5 % and 2.10 – 3.66 % , respectively
|
|
|
|
DiaSorin Prolactin |
|
|
|
- 1-step immunoluminometric sandwich assay using directly coated magnetic microparticles
- Sample matrix: Serum, EDTA plasma
- Sample volume: 25 µl
- Incubation time: 10 minutes
- Measuring range: 10 - 8000 mIU/L
- Detection Limit: 10 mIU/L
|
|
| |
|
|
|
|
|
Product code |
Product name |
Method |
Kit Size |
Sample Type |
|
824.050 |
BRAHMS Prolactin |
KRYPTOR TRACE Technology |
50 test kit |
Serum, plasma (heparin) |
|
312151 |
Liaison Prolactin |
1-step immunoluminometric sandwich assay |
100 test kit |
Serum, EDTA plasma |
|
P001909 |
PROL-CTK-4 (Prolactin) |
IRMA Coated tubes (RIA) |
100 tubes |
Serum, Plasma |
|
|
|
|
|
|
|
|
|
Back To Top |
|
|
|
|
|
|
|
|
|
Progesterone concentrations are useful in the documentation and timing of ovulation. Progesterone may also be useful in the evaluation of patients with sterility due to luteal phase defects. In order for Progesterone measurement to be useful as a sign of ovulation, it must be obtained as -closely as possible the mid-luteal phase of the cycle. Samples obtained too close to menses or within the 3 to 4 days of the LH peak can lead to confusing results. |
|
|
|
|
|
|
|
DiaSorin Progesterone |
|
|
|
- Competitive 1-step immunoluminometric assay using directly coated magnetic microparticles
- Sample matrix: Serum, plasma
- Sample volume: 75 µl
- Incubation time: 21 minutes
- Measuring range: 0.4 - 40 ng/ml
- Detection Limit: 0.4 ng/ml
|
|
| |
|
|
|
|
|
Product code |
Product name |
Method |
Kit Size |
Sample Type |
|
310420 |
Liaison Progesterone |
1-step immunoluminometric sandwich assay |
100 test kit |
Serum, EDTA plasma |
|
P001906 |
PROG-CTK-4 (Progesterone) |
RIA Coated Tubes |
100 tubes |
Serum, Plasma |
|
|
|
|
|
|
|
|
|
Back To Top |
|
| |
| |
|
|
| |
Testosterone measurement is indicated in males to diagnose hypogonadism and in
case of hormone replacement therapy (HRT) and in females for the diagnosis of
hirsutism, virilism and female infertility. In both genders Testosterone level
determination is used if a Testosterone producing tumor is suspected. |
|
| |
|
|
| |
DiaSorin Testosterone |
|
| |
- Competitive 1-step immunoluminometric assay using directly coated magnetic microparticles
- Sample matrix: Serum, plasma
- Sample volume: 100 µl
- Incubation time: 12 minutes
- Measuring range: 0.05 - 16 ng/ml
- Detection Limit: 0.05 ng/ml
|
|
| |
|
|
| |
|
Product code |
Product name |
Method |
Kit Size |
Sample Type |
|
310420 |
Liaison Testosterone |
Competitive 1-step immunoluminometric assay |
100 test kit |
Serum, plasma |
|
P3093 |
TESTO-CTK (Testosterone) |
RIA Coated Tubes |
100 Tubes |
Serum, plasma |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
Back To Top |
|
|
|
|
|
 |