Client SurveyCape Town
 
   
      
  Tumor  
   
   
     
  AFP  
  Alpha-fetoprotein (AFP) is used for the diagnosis, therapy control and follow-up of hepatocellular carcinomas and germ cell tumors  
     
  BRAHMS Kryptor AFP  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum, plasma (EDTA/heparin), amniotic Fluid
  • Diluent included in kit
  • Sample volume: 14 µl
  • Incubation time: 9 min
  • Direct measuring range: 0.23 – 700 ng/ml
  • Range with automated dilution: 0.23 – 500 000 ng/ml
  • Detection Limit: 0.23 ng/ml
  • Intra – assay and Inter-assay coefficients of variation are 2.63 – 4.63 % and 2.81 – 5.22 % , respectively
 
  DiaSorin Liaison AFP  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma, Amniotic Fluid
  • Sample volume: 25 µl
  • Incubation time: 20 min (10 min + 10 min)
  • Measuring range: 0.2 0 1000 IU/ml
  • Range with automated dilution: 0.23 – 500 000 ng/ml
  • Detection Limit: 0.2 IU/ml
 
 
Product code Product name Method Kit Size Sample Type
816.075 BRAHMS AFP KRYPTOR TRACE Technology 75 test kit Serum, plasma (heparin/EDTA) Amniotic Fluid
314471 Liaison AFP 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma, Amniotic Fluid
324471 IRMA-mat AFP IRMA Coated Tubes (RIA) 100 Tubes Serum, Amniotic Fluid
 
     
 
Back To Top      
  CA 125 II  
     
  Cancer antigen (CA 125 II) is used for the evaluation of the initial treatment efficacy, the long-term follow-up of patients in remission and the early detection of recurrence of disease or metastasis  
     
  BRAHMS Kryptor CA 125 II  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum, plasma (EDTA/heparin)
  • Diluent included in kit
  • Sample volume: 50 µl
  • Incubation time: 29 min
  • Direct measuring range: 0 – 600 U/ml
  • Range with automated dilution: 0 – 100 000 U/ml
  • Detection Limit: 1 U/ml
  • Inter-assay precision in the clinically relevant range is between 2.2 and 4.5 % CV
 
  DiaSorin Liaison CA 125 II  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Sample volume: 100 µl
  • Incubation time: 20 min (10 min + 10 min)
  • Measuring range: 0.2 - 1000 U/ml
  • Detection Limit: 0.2 U/ml
 
 
Product code Product name Method Kit Size Sample Type
805.075 BRAHMS CA 125 II KRYPTOR TRACE Technology 75 test kit Serum, plasma (heparin/EDTA)
314211 Liaison CA 125 II 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
R0053 CA 125II IRMA IRMA, Coated Tubes (RIA) 50 Tubes Serum, Plasma
 
 
   
Back To Top      
  CA 15-3  
     
  CA15-3 is used for therapy monitoring of breast cancer patients, the long-term follow-up of patients in remission and the early detection of recurrence of disease or metastasis  
     
  BRAHMS Kryptor CA 15-3  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum
  • Diluent included in kit
  • Sample volume: 8 µl
  • Incubation time: 14 min
  • Direct measuring range: 0.3 – 500 U/ml
  • Range with automated dilution: 0.3 – 40 000 U/ml
  • Detection Limit: 0.3 U/ml
  • Intra – assay and Inter-assay coefficients of variation are 0.4 – 1.0 % and 1.3 – 2.1 % , respectively
 
  DiaSorin Liaison CA 15-3  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Sample volume: 10 µl
  • Incubation time: 20 min (10 min + 10 min)
  • Measuring range: 0.3 - 1000 U/ml
  • Detection Limit: 0.3 U/ml
 
 
Product code Product name Method Kit Size Sample Type
808.075 BRAHMS CA 15-3 KRYPTOR TRACE Technology 75 test kit Serum
314301 Liaison CA 15-3 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
R0054 CA 15-3 IRMA IRMA, Coated Tubes (RIA) 50 Tubes Serum
 
     
  Back To Top    
 
  CA 19-9  
     
   CA19-9 is used for the diagnosis, follow-up and therapy control in patients with excretory pancreatic cancer, hepatobiliary and gastric cancer. It is also used for the early detection of recurrence of disease or metastasis  
     
  BRAHMS Kryptor CA 19-9  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum
  • Diluent included in kit
  • Sample volume: 50 µl
  • Incubation time: 14 min
  • Direct measuring range: 1.2 - 700 U/ml
  • Range with automated dilution: 1.2 – 600 000 U/ml
  • Detection Limit: 1.2 U/ml
  • Intra – assay and Inter-assay coefficients of variation are 1.4 – 3.0 % and 4.8 – 5.9 % , respectively
 
  DiaSorin Liaison CA 19-9  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Sample volume: 100 µl
  • Incubation time: 20 min (10 min + 10 min)
  • Measuring range: 0.3 - 1000 U/ml
  • Detection Limit: 0.3 U/ml
 
 
Product code Product name Method Kit Size Sample Type
807.100 BRAHMS CA 19-9 KRYPTOR TRACE Technology 100 test kit Serum
314171 Liaison CA 19-9 2-step immunoluminometric sandwich assay 100 test kit Serum, Plasma
R0055 CA19-9 IRMA IRMA, Coated Tubes (RIA) 50 Tubes Serum
 
 
   
Back To Top      
  CA 72-4  
     
  Monitor therapy and detect recurrence in patients with CA 72-4-positive cancer (gastrointestinal cancers)  
     
 
Product code Product name Method Kit Size Sample Type
R0056 CA 72-4 IRMA IRMA, Coated Tubes (RIA) 50 Tubes Serum
 
     
Back To Top    
 
  Calcitonin  
     
  Calcitonin is a tumor marker elevated in cases of medullary thyroid carcinoma and C-cell hyperplasia and is used in the diagnosis of these conditions. Medullary thyroid carcinoma (MTC) is a tumor of the CT-producing C-cells of the thyroid gland. Although a rare tumor, it can occur in a familial pattern as part of MEN (Multiple Endocrine Neoplasia) type II syndrome. These tumors usually produce diagnostically elevated serum concentrations of CT. Therefore, the immunoassay for CT in serum can be used to diagnose the presence of MTC with an exceptional degree of accuracy and specificity.  
     
  DiaSorin Liaison Calcitonin  
 
  • Direct, two-site, sandwich type immunoluminometric assay using directly coated magnetic microparticle
  • Sample matrix: Serum
  • Sample volume: 150 µl
  • Incubation time: 30 minutes
  • Measuring range: 1.0 - 2000 pg/ml
  • Detection Limit: 1.0 pg/ml
 
 
Product code Product name Method Kit Size Sample Type
310940 Liaison Calcitonin Direct, two-site, sandwich immunoluminometric assay 100 test kit Serum
BRAHMS Calcitonin RIA
 
 
Back To Top      
  CEA  
     
  Carcinoembryonic antigen (CEA) is used for colorectal cancer in the long-term follow-up of patients in remission, the evaluation of initial treatment efficacy and the early detection of recurrence or metastasis. Prognosis with a particular significant correlation in Duke’s S and D stages. CEA can also be found in other the following types of cancer (digestive tract, glanular cancer, breast, lung, ovary, bladder and thyroid)  
     
  BRAHMS Kryptor CEA  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum, plasma (heparin/EDTA)
  • Diluent included in kit
  • Sample volume: 70 µl
  • Incubation time: 39 min
  • Direct measuring range: 0.2 – 160 ng/ml
  • Range with automated dilution: 0.2 – 100 000 ng/ml
  • Detection Limit: 0.2 ng/ml
  • Intra – assay and Inter-assay coefficients of variation are 1.7 – 1.8 % and 3.3 – 4.9 % , respectively
 
  DiaSorin Liaison CEA  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma
  • Sample volume: 50 µl
  • Incubation time: 20 min (10 min + 10 min)
  • Measuring range: 0.2 - 1000 U/ml
  • Detection Limit: 0.2 U/ml
 
 
Product code Product name Method Kit Size Sample Type
817.100 BRAHMS CEA KRYPTOR TRACE Technology 100 test kit Serum
314311 Liaison CEA 2-step immunoluminometric sandwich assay 100 test kit Serum, plasma
324321 IRMA-coat CEA IRMA Coated Tube (RIA) 100 Tunes Serum, plasma
 
     
Back To Top    
 
  CYFRA 21-1  
     
  CYFRA 21-1 is used for the therapy monitoring and follow-up in patients suffering from Non-small Cell Lung Cancer (NSCLC). CYFRA 21-1 is also used for the prognosis factor for tumor stages I – III A vs III B in NSCLC and the follow-up control in urinary bladder cancer  
     
  Diasorin Liaison CYFRA 21-1  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum, plasma (heparin/EDTA)
  • Diluent included in kit
  • Sample volume: 70 µl
  • Incubation time: 19 min
  • Direct measuring range: 0.1 – 35 ng/ml
  • Range with automated dilution: 0.1 – 4000 ng/ml
  • Detection Limit: 0.1 ng/ml
  • Intra – assay and Inter-assay coefficients of variation are 2.3 - 3.6 % and 5.8 – 6.5 % , respectively
 
 
Product code Product name Method Kit Size Sample Type
811.050 BRAHMS CYFRA 21-1 KRYPTOR TRACE Technology 50 test kit Serum, plasma (heparin/EDTA)
 
 
   
Back To Top      
  Β2 – Microglobulin  
   
  Determination of β2-Microglobulin is used to monitor lymphoproliferative diseases (multiple myeloma, chronic lymphocytic lymphoma, non-Hodgkin’s lymphoma, Hodgkin’s disease) and to assess the renal function. In infectious diseases and inflammations serum β2-Microglobulin values can be elevated.  
     
  DiaSorin Liaison Β2 – Microglobulin  
 
  • 1-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, plasma, Urine
  • Sample volume: 10 µl
  • Incubation time: 10 min
  • Measuring range: 0.12 – 40 mg/L
  • Detection Limit: 0.12 mg/L
 
 
Product code Product name Method Kit Size Sample Type
314501 Liaison β2 - Microglobulin 1-step immunoluminometric sandwich assay 100 test kit Serum, plasma, Urine
 
     
Back To Top    
 
  NSE  
     
  Neuron specific enolase (NSE) in Small Cell Lung Carcinoma (SCLC) is used for the differential diagnosis, follow-up and therapy control. NSE is also used in neoroblastoma for follow-up and therapy control.  
     
  BRAHMS Kryptor NSE  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum
  • Diluent included in kit
  • Sample volume: 70 µl
  • Incubation time: 59 min
  • Direct measuring range: 0.8 – 200 ng/ml
  • Range with automated dilution: 0.8 – 10 000 ng/ml
  • Detection Limit: 0.8 ng/ml
  • Intra – assay and Inter-assay coefficients of variation are 1.5 – 2.9 % and 2.9 – 5.0 % , respectively
 
  Diasorin Liaison NSE  
 
  • 1-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum
  • Sample volume: 25 µl
  • Incubation time: 10 min
  • Measuring range: 0.04 – 200 µg/L
  • Detection Limit: 0.04 µg/L
 
 
Product code Product name Method Kit Size Sample Type
821.050 BRAHMS NSE KRYPTOR TRACE Technology 50 test kit Serum
314561 Liaison NSE 1-step immunoluminometric sandwich assay 100 test kit Serum
324560 Prolifigen NSE IRMA IRMA, Coated Tubes (RIA) 50 Beads Serum
 
 
   
Back To Top      
  PAP  
   
  Prostatic acid phosphatase (PAP) in combination with PSA or in cases of non-elevated PSA levels is used for the monitoring of patients with prostate cancer, detection of recurrence and follow-up of post therapeutic respoNSE. A prostate cancer with a high PAP level is related in more than 90% of cases to lymphnode involvement.  
     
  BRAHMS Kryptor PAP  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum
  • Diluent included in kit
  • Sample volume: 50 µl
  • Incubation time: 29 min
  • Direct measuring range: 0.1 – 50 ng/ml
  • Range with automated dilution: 0.1 – 15 000 ng/ml
  • Detection Limit: 0.1 ng/ml
  • Intra – assay and Inter-assay coefficients of variation are 0.7 – 2.4 % and 2.4 – 3.0 % , respectively
 
 
Product code Product name Method Kit Size Sample Type
822.050 BRAHMS PAP KRYPTOR TRACE Technology 50 test kit Serum
 
     
Back To Top    
 
  Total PSA  
     
  Prostate specific antigen (Total PSA) is used in Prostate cancer for therapy monitoring and follow-up control. Total PSA is also used for the early detection of relapse, especially after radical prostatectomy and for the screening of risk groups  
     
  BRAHMS Kryptor Total PSA  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum
  • Diluent included in kit
  • Sample volume: 50 µl
  • Incubation time: 19 min
  • Direct measuring range: 0 – 70 ng/ml
  • Range with automated dilution: 0 – 100 000 ng/ml
  • Detection Limit: 0.04 ng/ml
  • Intra – assay and Inter-assay coefficients of variation are 0.6 – 1.5 % and 2.1 % , respectively
 
  DiaSorin Liaison Total PSA  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, Plasma
  • Sample volume: 50 µl
  • Incubation time: 20 min (10 min + 10 min)
  • Measuring range: 0.09 – 300 ng/L
  • Detection Limit: 0.09 ng/L
 
 
Product code Product name Method Kit Size Sample Type
810.100 BRAHMS Total PSA KRYPTOR TRACE Technology 100 test kit Serum
314381 Liaison PSA 2-step immunoluminometric sandwich assay 100 test kit Serum, Plasma
R0014 PSA total IRMA IRMA, Coated Tubes (RIA) 100 Tubes Serum, Plasma
 
 
   
Back To Top      
  Free PSA  
     
  Free PSA is used in combination with Total PSA for the improved discrimination between prostate cancer and BPH to reduce the number of unnecessary biopsies. Free PSA is also used in combination with PSA for increased sensitivity and specificity for the detection of prostate cancer.  
     
  BRAHMS Kryptor Free PSA  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum, plasma (heparin/EDTA)
  • Diluent included in kit
  • Sample volume: 70 µl
  • Incubation time: 29 min
  • Direct measuring range: 0 – 15 ng/ml
  • Detection Limit: 0.02 ng/ml
  • Intra – assay and Inter-assay coefficients of variation are 0.5 – 5.2 % and 1.5 – 5.8 % , respectively
 
  DiaSorin Liaison Free PSA  
 
  • 1-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, Plasma
  • Sample volume: 50 µl
  • Incubation time: 10 minutes
  • Measuring range: 0.04 – 25 ng/L
  • Detection Limit: 0.04 ng/L
 
 
Product code Product name Method Kit Size Sample Type
867.050 BRAHMS Free PSA KRYPTOR TRACE Technology 50 test kit Serum
314391 Liaison fPSA 1-step immunoluminometric sandwich assay 100 test kit Serum, plasma
R0015 PSA free IRMA IRMA, Coated Tubes (RIA) 50 Tubes Serum, plasma
 
     
Back To Top    
 
  S100  
     
  S-100 is a reliable tumor marker mainly in metastatic melanoma where it reflects the tumor load and prognosis. S-100 has also been described to be a valuable marker for monitoring and follow-up of melanoma patients. S-100 follows the course of the disease and has been shown to be an early indicator of relapse. It could therefore be a valuable adjunct to imaging and clinical assessment.  
     
  Another important clinical application for S-100 is as a marker for different forms of cerebral lesions. Clinical studies have demonstrated an immediate increase of S-100 in the circulation after a brain injury indicating a fast release of brain S-100 into the blood.  
     
  S-100B is a very sensitive marker for an injury of the brain caused by head trauma and is released at the time of the primary injury. The level in serum strongly correlates with the severity of the primary trauma and the outcome of the patient. In patients with global cerebral ischemia, it has been reported that a positive value in the serum 24 hours after ischemia is an independent predictor of not regaining consciousness. S-100 has also been shown to be a useful marker in stroke and birth asphyxia.  
     
  DiaSorin Liaison S100  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum, CSF
  • Sample volume: 100 µl
  • Incubation time: 20 min (10 min + 10 min)
  • Measuring range: 0.02 – 30 µg/L
  • Detection Limit: 0.02 µg/L
 
 
Product code Product name Method Kit Size Sample Type
314701 Liaison S100 2-step immunoluminometric sandwich assay 100 test kit Serum, CSF
364701 S100 ELISA ELISA 96 wells Serum, CSF
 
 
   
Back To Top      
  SCC  
   
  Squamous cell carcinoma (SCC) is used in cervical cancer for the long-term follow-up of patients in remission. SCC is used in the evaluation of initial treatment efficacy in cervical cancer and the detection of recurrence or metastasis. SCC can also be found in other types of cancer (squamous cell lung cancer, head and neck cancer, esophageal cancer).  
     
  BRAHMS Kryptor SCC  
 
  • TRACE technology (Time resolved amplified cryptate emission)
  • Sample matrix: Serum
  • Diluent included in kit
  • Sample volume: 50 µl
  • Incubation time: 44 min
  • Direct measuring range: 0.1 – 100 µg/L
  • Range with automated dilution: 0.1 – 500 µg/L
  • Detection Limit: 0.1 µg/L
  • Intra – assay and Inter-assay coefficients of variation are 1.8 – 2.3 % and 3.5 – 4.3 % , respectively
 
 
Product code Product name Method Kit Size Sample Type
812.050 BRAHMS SCC KRYPTOR TRACE Technology 50 test kit Serum
 
     
Back To Top    
 
  TK  
     
  Thymidine Kinase (TK) is an essential enzyme which is expressed in cell division activity. An increased level of cell division is linked to malignant tumor diseases, such as leukemia and lymphomas.  
     
  DiaSorin Liaison TK  
 
  • Indirect, modified 2-step competitive chemiluminescence immunoassay
  • Sample matrix: Serum, EDTA Plasma
  • Sample volume: 200 µl
  • Incubation time: 60 min
  • Measuring range: 0.5 – 100 U/L
  • Detection Limit: 0.5 U/L
 
 
Product code Product name Method Kit Size Sample Type
310960 Liaison TK 2-step competitive chemiluminescent immunoassay 100 test kit Serum, EDTA plasma
324250 Prolifigen TK-REA REA Separator Tablets (RIA) 50 Tables Serum
 
 
   
Back To Top      
  TPA-M  
   
  Tissue polypeptide antigen (TPA®) in human serum is used for the management of patients with tumors arising from epithelial cells, e.g. carcinomas of the lung, breast, gastrointestinal tract, and urinary bladder.  
     
  DiaSorin Liaison TPA-M  
 
  • 2-step immunoluminometric sandwich assay using directly coated magnetic microparticles
  • Sample matrix: Serum
  • Sample volume: 100 µl
  • Incubation time: 20 min (10 min + 10 min)
  • Measuring range: 2 – 4000 U/L
  • Detection Limit: 2 U/L
 
 
Product code Product name Method Kit Size Sample Type
314121 Liaison TPA-M 2-step immunoluminometric sandwich assay 100 test kit Serum
324121 Prolifigen TPA-M IRMA IRMA, Coated Tubes (RIA) 100 Beads Serum
 
     
Back To Top    
 
 

LINKS

http://www.brahms.de/

http://www.diasorin.com/

 
 
Copyright © Humor Diagnostica